SECTION 21 -
SPENCER FRANKLIN HYDRACLAMP, HYDRAULICS
AND PNEUMATICS
WDS
&
0845 606 66 77
•
:
www.wdsltd.co.uk•
*
sales@wdsltd.co.uk21-38
WDS
www.wdsltd.co.ukPowRlock Lever Pump
SF-OE00690/
OE00691
G
H
F
J
M
N (FIXING HOLES
M8 x 12 DEEP)
K
A
B
C
D
E
F
P
Q
CL OF FIXING HOLES
PORTS 1/8" B.S.P. WITH 13.5 SPOTFACE (SEAL WITH COPPER WASHER )
OE00690
Fluid Capacity
cm³
Displacement per
Cycle cm³
Normal Operating
Pressure kg/cm²
Max Pressure
kg/cm²
Weight kg WDS No.
Seal Kit No.
163.87
4.91
141
175
3.17
SF-OE00690 SF-4405
327.74
4.91
141
175
3.4
SF-OE00691 SF-4405
Dimensions in mm
A
B
C
D
E
F
G
H
J
N
P
Q WDS No.
167.4 135.73 57.15 317.5 64.76 298.45 63.5 63.5 26.98 12.7 117.5 29.4 SF-OE00690
237.49 205.74 127 307.35 64.76 298.45 63.5 63.5 26.98 12.7 187.2 29.4 SF-OE00691
Note: Exchange unit available.
- All dimensions in millimeters
- K-release knob (anti-clockwise to release)
- M-port may be used as additional outlet
- Double acting lever pumps must be installed with lever
mechanism and plunger at the top - maximum tilt from
vertical 30°
- Internal relief valve set to limit pressure to 175kg/cm² -
it is adjustable
Re
fer to page 21-46 & 21-47 for
more technical information