SECTION 21 -

SPENCER FRANKLIN HYDRACLAMP, HYDRAULICS

AND PNEUMATICS

WDS

&

0845 606 66 77

:

www.wdsltd.co.uk

*

sales@wdsltd.co.uk

21-46

WDS

www.wdsltd.co.uk

P

oil

F

A

p

A

out

Spencer Franklin Information Sheet

Actual pressures can be up to 10% less than theoretical due to system losses.

When using the calculations please use the units given in the table.

Ram Information

Symbol Unit

Definition

mm Maximum stroke in millimetres

F

N

Clamping force in Newtons

A

p

cm

2

Internal surface area of the piston (effective area in catalogue tables)

A

out

cm

2

Output surface area of the ram or the output surface area of the fixture

attached

P

oil

Bar Oil pressure in bar

P

out

Bar Output clamping pressure in bar

P

air

Bar Air input pressure for booster in bar

R

N/A Ratio of booster

V

o

cm

3

Volume of oil required for maximum stroke

Key

Booster Information

= ×

×

=

= × × 10

(

)

= ×

× 9.81

*Select a booster 15-20% greater than

the calculated volume, to allow for

expansion.

Available for the past 60 years the range is particularly suitable for simple clamping and presswork

applications. Using mainly single acting spring return cylinders the range offers a simple and economical

solution to clamping and presswork problems.

Air/Oil boosters and pumps are usually part of the above systems

so the only service required is a

compressed air supply.

Air Input

Optional Oil

Reservoir

Breather Plug

Oil Output

Ports